DataSheet.in

A8GS डेटा पत्रक PDF( Datasheet डाउनलोड )


डेटा पत्रक - Remote Reset Rocker Switch - Omron

भाग संख्या A8GS
समारोह Remote Reset Rocker Switch
मैन्युफैक्चरर्स Omron 
लोगो Omron लोगो 
पूर्व दर्शन
1 Page
		
<?=A8GS?> डेटा पत्रक पीडीएफ

A8GS pdf
A8GS
Contact Form
1 to 4: Power contact terminal
+, -: Coil terminal
Terminals
Reset voltage
Marking on caps
No Marking
DPST
Power contact terminal × 2
+1
2
-3
Quick-connect terminals
#187 (t=0.8)
5V model
3.3V model
A8GS-D1185
A8GS-D1183
A8GS-D1285
A8GS-D1283
A8GS-D1385
A8GS-D1383
4
Solder terminals
5V model
A8GS-D1115
A8GS-D1215
3.3V model
A8GS-D1113
A8GS-D1213
A8GS-D1315
A8GS-D1313
Quantity
per box
50
Note: 1. [ V ] is shown at the end of model name for TV-8 approved models. (Example : A8GS-P1185V, A8GS-C1185V, A8GS-D1185V)
Note: 2. TV-8 approved model is only for Power switch circuit.
Note: 3. [ 3 ] is shown at the end of model name for reset voltage 3.3 VDC models. (Example : A8GS-P1183).
[ 5 ] is shown at the end of model name for reset voltage 5 VDC models. (Example : A8GS-P1185).
2. Without Reset function type
Contact Form
1 to 4: Power contact terminal
Micro load contact
terminal × 1
a, b: Micro load contact terminal
SPST
Power contact terminal × 1
12
Terminals
Marking on caps
No Marking
ab
CT Connector
A8GS-S1100
A8GS-S1200
A8GS-S1300
Quick-connect
terminals
#187 (t=0.8)
A8GS-P1180
A8GS-P1280
A8GS-P1380
Solder
terminals
A8GS-P1110
A8GS-P1210
A8GS-P1310
DPST
Power contact terminal × 2
12
3
Quick-connect
terminals
#187 (t=0.8)
A8GS-D1180
A8GS-D1280
A8GS-D1380
4
Solder
terminals
A8GS-D1110
A8GS-D1210
A8GS-D1310
Quantity
per box
50
Contact Form
1 to 2 Power contact terminal
a, b: Micro load contact terminal
Terminals
No Marking
DPST
Micro load contact terminal × 1 + Power contact terminal × 1
12
a
Micro load contact terminal : CT Connector
Power contact terminal : Quick-connect
terminals #187 (t=0.8)
A8GS-C1180
b
Micro load contact terminal : CT Connector
Power contact terminal : Solder terminals
A8GS-C1110
Marking on caps
A8GS-C1280
A8GS-C1210
A8GS-C1380
A8GS-C1310
Note: 4. These models are without reset function, it has same function with standard Rocker switch.
Quantity
per box
50
Ratings
Contact Ratings
Rated voltage
Rated current
(Resistive load)
Power contact terminal
125 VAC
250 VAC
16 A
10 A
Micro load contact terminal
5 VDC
0.2 A
Note: 1. The above ratings were tested under the following conditions:
(1) Ambient temperature : 20 ± 2 °C
(2) Ambient humidity : 65 ± 5 % RH
(3) Switching frequency : 7 times/min
Reset Coil Ratings
Model
Rated voltage,
current
Operating
voltage range
Rated usage cycle
Coil resistance
(Coil temperature: 20 ± 2 °C)
Reset voltage : 5V model
(A8GS-@@@@5)
5VDC 455 mA
4.5 to 5.5 VDC
ON: 50 to 100 ms
OFF: Min 5 sec
11 Ω ± 20 %
Reset voltage : 3.3V model
(A8GS-@@@@3)
3.3VDC 300 mA
3.0 to 3.6 VDC
ON: 50 to 100 ms
OFF: Min 5 sec
11 Ω ± 20 %
Note: 1. Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle.
Otherwise the performance of the coil may be deteriorated.
Note: 2. In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative.
2

विन्यास 8 पेज
डाउनलोड[ A8GS Datasheet.PDF ]


शेयर लिंक


अनुशंसा डेटापत्रक

भाग संख्याविवरणविनिर्माण
A8GReset Rocker SwitchOmron
Omron
A8GSRemote Reset Rocker SwitchOmron
Omron


भाग संख्याविवरणविनिर्माण
30L120CTSchottky RectifierPFC Device
PFC Device
AT28C010-12DKSpace 1-MBit (128K x 8) Paged Parallel EEPROMATMEL
ATMEL
B20NM50FDN-CHANNEL POWER MOSFETSTMicroelectronics
STMicroelectronics
D8442SD844SavantIC
SavantIC
FAE391-A20AM/FM Automotive Electronic TunerMitsumi
Mitsumi


Index : 0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z



www.DataSheet.in    |   2017   |  संपर्क   |   खोज     |   English